ترموستات ديجيتال دما و رطوبت روپنلی XY-WTH1
ولتاژ کاري 6 الي 30 ولت DC
Digital display high precision dual output temperature and humidity control module
Details:
- Control accuracy: 0.1’C / 0.1%RH
- Detection probe: integrated sensor
- Output type: relay output
- Output capacity: up to 10A
Temperature function is as follows:
- The automatic identification of work mode:
- The system automatically according to the start/stop temperature, identify work mode;
- Start temperature > stop temperature, cooling mode ‘C’.
- Start temperature < stop temperature, heating mode ‘H’.
- Cooling mode:
- When the temperature >= Start temperature, relay conduction, red led on, refrigeration equipment begin to work;
- When the temperature <= Stop temperature, relay disconnect, red led off, refrigeration equipment stop to work;
- Heating mode:
- When the temperature <= Start temperature, relay conduction, red led on, heating equipment begin to work;
- When the temperature >= Stop temperature, relay disconnect, red led off, heating equipment stop to work;
- Temperature correction function OFE (-10’C ~ 10’C):
- The system is working for a long time and may be biased, through this function correctly, the actual temperature = measuring temperature + calibration value;
The humidity function is as follows:
- The automatic identification of work mode:
- The system automatically according to the start/stop humidity, identify work mode;
- Start humidity > stop humidity, dehumidification mode ‘D’.
- Start humidity < stop humidity, humidification mode ‘E’.
- Dehumidification mode:
- When the humidity >= Start humidity, relay conduction, green led on, dehumidification equipment begin to work;
- When the humidity <= Shop humidity, relay disconnect, green led off, dehumidification equipment stops to work;
- Humidification mode:
- When the humidity <= Start humidity, relay conduction, green led on, humidification equipment begin to work;
- When the humidity >= Shop humidity, relay disconnect, green led off, humidification equipment stops to work;
- Humidification correction function RH (-10.0 ~ 10%):
- The system is working for a long time and may be biased, through this function correctly, the actual humidity= measuring humidity + calibration value;
دیدگاهها
هیچ دیدگاهی برای این محصول نوشته نشده است.